New Results and Experiences of Continuous Dioxin Monitoring by Using of AMESA
Oct 06 2014
Author: Jürgen Reinmann on behalf of CEM
Introduction
The continuous monitoring of dioxin and furan emissions of incinerators is a topic which has been discussed globally over the last several years. Even though a continuous on-line monitoring system would be the optimum solution, up to now no online-system is available which is able to give an information of the PCDD/PCDF emissions as TEQ value, as demanded by EN-19481 or the new EU directive for incineration of waste 2000/76/EC2. According last reports, such systems will be not available in the next few years.
Therefore, long-term sampling using AMESA could close the gap between reality and target results. AMESA provides more informations on dioxin emissions than the usual short-term collection of samples over a few hours on 1 – 3 selected days per year. In Germany continuous emission measurement and control in accordance with §10 (1) of the 17th Federal Emission Control Ordinance (17. BImSchV)3 must be carried out using a suitable (performance-tested) measuring device. Due to this regulation we decided to do a performance test for AMESA by TÜV Rheinland in 1997.
Since the first installations of the TUV approved AMESA systems in 1997, AMESA became more and more as a standard for continuous dioxin control in Europe. More than 70 installations give a lot of information’s. After starting of the continuous dioxin emission control in the Wallonia region with the 1st January 2001, in this area exist now experiences of the dioxin emissions of more than 3 years4.
Since the start-up of this network more than 700 samples of duration of 2 weeks ware taken from 12 burners of household waste incinerators. After 20 occasions, in which the limit value of 0,1 TEQ ng/Nm3 was exceeded in the first year 2001, this quantity was reduced to 9 occasions in year 2002 and 12 occasions in year 2003. Therefore some plants had to be modernised to fulfil the regulations. Of course, these leaded at first to new investments, but after these investments, the operators had an instrument to calm down the public by showing continuously that their plants were running properly and the environmental stress was reduced.
This report will give you an introduction into the AMESA system, realised applications, newest results and some remarks to the new version of EN-1948-1.
Digital Edition
Asian Environmental Technology 27.2 - April/May 2023
May 2023
In This Edition Business News - Celebrating The Life Of A Gas Measurement Industry Icon - A New Home For Gas Sensor Specialists - Envea Completes The Acquisition Of Hycontrol Ltd Environ...
View all digital editions
Events
Jul 02 2023 Albena, Bulgaria
Jul 04 2023 Cardiff, UK
Jul 05 2023 Johannesburg, South Africa
Jul 11 2023 Shanghai, China
Jul 11 2023 Lagos, Nigeria